Subject: water underflow weir oil.proc. Добрый день,помогите, пожалуйста, с переводом water underflow weir в следующем контексте:
Specification of LZA(HH). In the case of a settler with an overflow weir LZA(HH) is not a trip level in the real sense. It will be used here to indicate the maximum acceptable liquid level. 4. Specification of LZA(HH) and IL. (IL can be adjusted during the calculations). 5. The maximum allowable gas load factor, λmax, in the gas cap above LZA(HH). In the case of bulk separation with no demisting internals: λmax = 0.07 m/s. 6. The height of the passage underneath the water underflow weir (at least 0.2 m) and the distance between the water underflow and water overflow weir typically 0.2 m). 7. Collection compartments: required minimum control times. 8. Specification of foam allowance and/or dispersion band Заранее спасибо
|