DictionaryForumContacts

 Des

link 26.09.2008 14:03 
Subject: противопожарная перегородка с дверьми для пропуска людей
Пожалуйста, помогите перевести.

Заранее спасибо

 Олег3

link 26.09.2008 14:57 
Fire curtain with a door opening in it ??????

 Des

link 26.09.2008 15:54 
Олег,спасибо за помощь! А можно спросить?Вы имеете дело с техническими переводами?

 tumanov

link 26.09.2008 16:42 
curtain - это очень вряд-ли

Types

There are two main classifications of fire walls: fire partitions, and true fire walls. To the layperson, the common use of language typically includes both when referring to a firewall unless distinguishing between them is necessary.

* A fire wall is a wall separating buildings or subdividing a building to prevent the spread of fire and having a fire resistance rating and structural stability. [1].

There is a further sub-classification of fire walls. A High Challenge Fire Wall is a wall used to separate buildings or subdivide a building with high fire challenge occupancies, having enhanced fire resistance ratings and enhanced appurtenance protection to prevent the spread of fire, and having structural stability.[2]

Portions of structures that are subdivided by fire walls are permitted to be considered separate buildings, in that fire walls have sufficient structural stability to maintain the integrity of the wall in the event of the collapse of the building construction on either side of the wall.[3]

* A fire barrier wall, also referred to as a fire partition, is a fire rated wall assembly which is not a fire wall. Typically, the main differences is that a fire barrier wall is not structurally stable, and does not extend through the roof, or to the underside of the floor above.[4]

Fire barrier walls are continuous from an exterior wall to an exterior wall, or from a floor below to a floor or roof above, or from one fire barrier wall to another fire barrier wall, fire wall, or high challenge fire wall having a fire resistance rating of at least equal rating as required for the fire barrier wall. They are continuous through all concealed spaces (e.g., above a ceiling), but are not required to extend through concealed spaces if the construction assembly forming the bottom of the space has a fire resistance rating at least equal of the fire barrier wall.[5]

 tumanov

link 26.09.2008 16:46 

 Des

link 26.09.2008 16:56 
Спасибо огромное,Туманов :) очень и очень познавательно. А вы где-нибудь встречали подобное выражение?

 tumanov

link 26.09.2008 17:26 
У меня где-то полтора года назад был скачан мануал американский для пожарников с подробными классификациями, терминами и определениями.
К сожалению на компьютере столько справочного материала, что я его не нашел быстро. Был вынужден воспользоваться википедией.
Однако эти термины встречались мне именно при переводе текста об испытании строительных материалов на огнестойкость.
Так что я в некоторой степени уверен. Особенно в partitions.

 