Subject: End-scale deflection gen.

A display instrument is to be connected that indicates a pressure from 0...10 bar (e.g. for the lube oil
pressure downstream of the filter). The instrument indicates 0 bar at a voltage of one Volt. ***End-scale deflection is reached at 10 V. The corresponding sensor outputs 0 to 5 V for a pressure range of 0...10 bar (linear, 0 Volt at 0 bar and 5 V at 10 bar).

Спасибо!

 Gennady1

link 10.01.2012 8:36 
отклонение стрелки на полную шкалу происходит при напряжении 10 В

 adelaida

link 10.01.2012 11:25 
Большое Вам спасибо.

 