Subject: synthesis gas compressor in vendor package
1.2.3 Synthesis Area Instrumentation and Control

Our company recommends that the following instrumentation, safety logic and control issues are addressed by your company:
• Update the compressor curves for the synthesis gas compressor in vendor package in order to restore anti-surge control to good working order
• Repair or replace the steam let down valve PV-8401. You should consider this a high priority since it impacts both the efficiency and reliability of the plant.
• Consider implementing HIGH-HIGH reactor Bed temperature alarms
• Modify Recycle gas pressure control strategy changes as described in section 3.4.3
• You should consider replacing all butterfly valves used in for reactor bed temperature control with a different type for improved resolution and bed temperature control.

 justboris

link 5.07.2007 10:14 
компрессор синтез-газа в заводской комплектации ???

 Bigor

link 5.07.2007 10:27 
имхо
компрессорный агрегат в комплектации поставщика

сам компрессор может производиться одним изготовителем, а агрегат на его основе - комплектоваться другим поставщиком (vendor/packager)

 Susan

link 6.07.2007 7:59 
Bigor +1

 